043572d5444116b9d9ad8ae763cf069e7accbc30 upstream.
Temperature limit clamps are applied after converting the temperature
from milli-degrees C to degrees C, so either the clamp limit needs
to be specified in degrees C, not milli-degrees C, or clamping must
happen before converting to degrees C. Use the latter method to avoid
overflows.
vrm is an u8, so the written value needs to be limited to [0, 255].
Cc: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Reviewed-by: Jean Delvare <jdelvare@suse.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
*/
static inline s8 TEMP_TO_REG(int val)
{
- return clamp_val(SCALE(val, 1, 1000), -128000, 127000);
+ return SCALE(clamp_val(val, -128000, 127000), 1, 1000);
}
static inline int TEMP_FROM_REG(s8 val)
err = kstrtoul(buf, 10, &val);
if (err)
return err;
+ if (val > 255)
+ return -EINVAL;
data->vrm = val;
return count;