[ Upstream commit
4bc83b3f272fe8f36450f9c003df49cf07ffe5fd ]
In the case when the phy_mask is bitwise anded with the phy_index bit is
zero the continue statement currently jumps to the next iteration of the
while loop and phy_index is never actually incremented, potentially
causing an infinite loop if phy_index is less than SCI_MAX_PHS. Fix this
by turning the while loop into a for loop.
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Signed-off-by: Sasha Levin <alexander.levin@microsoft.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
* Note: We have not moved the current phy_index so we will actually
* compare the startting phy with itself.
* This is expected and required to add the phy to the port. */
- while (phy_index < SCI_MAX_PHYS) {
+ for (; phy_index < SCI_MAX_PHYS; phy_index++) {
if ((phy_mask & (1 << phy_index)) == 0)
continue;
sci_phy_get_sas_address(&ihost->phys[phy_index],
&ihost->phys[phy_index]);
assigned_phy_mask |= (1 << phy_index);
- phy_index++;
}
}