#define IT87_REG_FAN_MAIN_CTRL 0x13
#define IT87_REG_FAN_CTL 0x14
#define IT87_REG_PWM(nr) (0x15 + (nr))
+#define IT87_REG_PWM_DUTY(nr) (0x63 + (nr) * 8)
#define IT87_REG_VIN(nr) (0x20 + (nr))
#define IT87_REG_TEMP(nr) (0x29 + (nr))
u8 fan_main_ctrl; /* Register value */
u8 fan_ctl; /* Register value */
- /* The following 3 arrays correspond to the same registers. The
- * meaning of bits 6-0 depends on the value of bit 7, and we want
- * to preserve settings on mode changes, so we have to track all
- * values separately. */
+ /* The following 3 arrays correspond to the same registers up to
+ * the IT8720F. The meaning of bits 6-0 depends on the value of bit
+ * 7, and we want to preserve settings on mode changes, so we have
+ * to track all values separately.
+ * Starting with the IT8721F, the manual PWM duty cycles are stored
+ * in separate registers (8-bit values), so the separate tracking
+ * is no longer needed, but it is still done to keep the driver
+ * simple. */
u8 pwm_ctrl[3]; /* Register value */
- u8 pwm_duty[3]; /* Manual PWM value set by user (bit 6-0) */
+ u8 pwm_duty[3]; /* Manual PWM value set by user */
u8 pwm_temp_map[3]; /* PWM to temp. chan. mapping (bits 1-0) */
/* Automatic fan speed control registers */
data->fan_main_ctrl);
} else {
if (val == 1) /* Manual mode */
- data->pwm_ctrl[nr] = data->pwm_duty[nr];
+ data->pwm_ctrl[nr] = data->type == it8721 ?
+ data->pwm_temp_map[nr] :
+ data->pwm_duty[nr];
else /* Automatic mode */
data->pwm_ctrl[nr] = 0x80 | data->pwm_temp_map[nr];
it87_write_value(data, IT87_REG_PWM(nr), data->pwm_ctrl[nr]);
return -EINVAL;
mutex_lock(&data->update_lock);
- data->pwm_duty[nr] = pwm_to_reg(data, val);
- /* If we are in manual mode, write the duty cycle immediately;
- * otherwise, just store it for later use. */
- if (!(data->pwm_ctrl[nr] & 0x80)) {
- data->pwm_ctrl[nr] = data->pwm_duty[nr];
- it87_write_value(data, IT87_REG_PWM(nr), data->pwm_ctrl[nr]);
+ if (data->type == it8721) {
+ /* If we are in automatic mode, the PWM duty cycle register
+ * is read-only so we can't write the value */
+ if (data->pwm_ctrl[nr] & 0x80) {
+ mutex_unlock(&data->update_lock);
+ return -EBUSY;
+ }
+ data->pwm_duty[nr] = pwm_to_reg(data, val);
+ it87_write_value(data, IT87_REG_PWM_DUTY(nr),
+ data->pwm_duty[nr]);
+ } else {
+ data->pwm_duty[nr] = pwm_to_reg(data, val);
+ /* If we are in manual mode, write the duty cycle immediately;
+ * otherwise, just store it for later use. */
+ if (!(data->pwm_ctrl[nr] & 0x80)) {
+ data->pwm_ctrl[nr] = data->pwm_duty[nr];
+ it87_write_value(data, IT87_REG_PWM(nr),
+ data->pwm_ctrl[nr]);
+ }
}
mutex_unlock(&data->update_lock);
return count;
* channels to use when later setting to automatic mode later.
* Use a 1:1 mapping by default (we are clueless.)
* In both cases, the value can (and should) be changed by the user
- * prior to switching to a different mode. */
+ * prior to switching to a different mode.
+ * Note that this is no longer needed for the IT8721F and later, as
+ * these have separate registers for the temperature mapping and the
+ * manual duty cycle. */
for (i = 0; i < 3; i++) {
data->pwm_temp_map[i] = i;
data->pwm_duty[i] = 0x7f; /* Full speed */
static void it87_update_pwm_ctrl(struct it87_data *data, int nr)
{
data->pwm_ctrl[nr] = it87_read_value(data, IT87_REG_PWM(nr));
- if (data->pwm_ctrl[nr] & 0x80) /* Automatic mode */
+ if (data->type == it8721) {
data->pwm_temp_map[nr] = data->pwm_ctrl[nr] & 0x03;
- else /* Manual mode */
- data->pwm_duty[nr] = data->pwm_ctrl[nr] & 0x7f;
+ data->pwm_duty[nr] = it87_read_value(data,
+ IT87_REG_PWM_DUTY(nr));
+ } else {
+ if (data->pwm_ctrl[nr] & 0x80) /* Automatic mode */
+ data->pwm_temp_map[nr] = data->pwm_ctrl[nr] & 0x03;
+ else /* Manual mode */
+ data->pwm_duty[nr] = data->pwm_ctrl[nr] & 0x7f;
+ }
if (has_old_autopwm(data)) {
int i;