When calculate temperature, old code firstly do division and then
convert to "millicelsius" unit. This will lose resolution and only can
read back temperature with "Celsius" unit.
So firstly scale step value to "millicelsius" and then do division, so
finally we can increase resolution for temperature value. Also refine
the calculation from temperature value to step value.
Signed-off-by: Leo Yan <leo.yan@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
* Every step equals (1 * 200) / 255 celsius, and finally
* need convert to millicelsius.
*/
- return (HISI_TEMP_BASE + (step * 200 / 255)) * 1000;
+ return (HISI_TEMP_BASE * 1000 + (step * 200000 / 255));
}
static inline long _temp_to_step(long temp)
{
- return ((temp / 1000 - HISI_TEMP_BASE) * 255 / 200);
+ return ((temp - HISI_TEMP_BASE * 1000) * 255) / 200000;
}
static long hisi_thermal_get_sensor_temp(struct hisi_thermal_data *data,