Fixed regulators in twl6030 do not have set_voltage hook.
Regulator core returns -22 if set_voltage is NULL and apply_uV is set
while applying the constraint to set voltage resulting in failure during probe
of these regulators.
Do not set apply_uV for fixed regulators which don't have set_voltage.
machine_constraints_voltage: VANA: failed to apply 2100000uV constraint
twl_reg twl_reg.43: can't register VANA, -22
twl_reg: probe of twl_reg.43 failed with error -22
machine_constraints_voltage: VCXIO: failed to apply 1800000uV constraint
twl_reg twl_reg.44: can't register VCXIO, -22
twl_reg: probe of twl_reg.44 failed with error -22
machine_constraints_voltage: VDAC: failed to apply 1800000uV constraint
twl_reg twl_reg.45: can't register VDAC, -22
twl_reg: probe of twl_reg.45 failed with error -22
Signed-off-by: Balaji T K <balajitk@ti.com>
Signed-off-by: Tony Lindgren <tony@atomide.com>
.constraints = {
.min_uV = 2100000,
.max_uV = 2100000,
- .apply_uV = true,
.valid_modes_mask = REGULATOR_MODE_NORMAL
| REGULATOR_MODE_STANDBY,
.valid_ops_mask = REGULATOR_CHANGE_MODE
.constraints = {
.min_uV = 1800000,
.max_uV = 1800000,
- .apply_uV = true,
.valid_modes_mask = REGULATOR_MODE_NORMAL
| REGULATOR_MODE_STANDBY,
.valid_ops_mask = REGULATOR_CHANGE_MODE
.constraints = {
.min_uV = 1800000,
.max_uV = 1800000,
- .apply_uV = true,
.valid_modes_mask = REGULATOR_MODE_NORMAL
| REGULATOR_MODE_STANDBY,
.valid_ops_mask = REGULATOR_CHANGE_MODE
.constraints = {
.min_uV = 2100000,
.max_uV = 2100000,
- .apply_uV = true,
.valid_modes_mask = REGULATOR_MODE_NORMAL
| REGULATOR_MODE_STANDBY,
.valid_ops_mask = REGULATOR_CHANGE_MODE
.constraints = {
.min_uV = 1800000,
.max_uV = 1800000,
- .apply_uV = true,
.valid_modes_mask = REGULATOR_MODE_NORMAL
| REGULATOR_MODE_STANDBY,
.valid_ops_mask = REGULATOR_CHANGE_MODE
.constraints = {
.min_uV = 1800000,
.max_uV = 1800000,
- .apply_uV = true,
.valid_modes_mask = REGULATOR_MODE_NORMAL
| REGULATOR_MODE_STANDBY,
.valid_ops_mask = REGULATOR_CHANGE_MODE