lm87_init_client() conditionally sets the Start bit and clears the
INT#_Clear bit in the Config 1 register. The condition should be that
either of these bits needs changing, but currently it checks the
(self-clearing) Initialization bit instead of INT#_Clear.
Fix the condition and also ensure we never set the Initialization bit.
Signed-off-by: Ben Hutchings <bhutchings@solarflare.com>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
lm87_write_value(client, LM87_REG_IN_MAX(0), 0xFF);
}
}
- if ((config & 0x81) != 0x01) {
- /* Start monitoring */
+
+ /* Make sure Start is set and INT#_Clear is clear */
+ if ((config & 0x09) != 0x01)
lm87_write_value(client, LM87_REG_CONFIG,
- (config & 0xF7) | 0x01);
- }
+ (config & 0x77) | 0x01);
}
static int lm87_remove(struct i2c_client *client)