- reg: Base address and length of each register bank used by the external
IRQ pins driven by the interrupt controller hardware module. The base
addresses, length and number of required register banks varies with soctype.
-
+- interrupt-controller: Identifies the node as an interrupt controller.
- #interrupt-cells: has to be <2>: an interrupt index and flags, as defined in
- interrupts.txt in this directory
+ interrupts.txt in this directory.
+- interrupts: Must contain a list of interrupt specifiers. For each interrupt
+ provided by this irqpin controller instance, there must be one entry,
+ referring to the corresponding parent interrupt.
Optional properties:
if different from the default 4 bits
- control-parent: disable and enable interrupts on the parent interrupt
controller, needed for some broken implementations
+- clocks: Must contain a reference to the functional clock. This property is
+ mandatory if the hardware implements a controllable functional clock for
+ the irqpin controller instance.
+- power-domains: Must contain a reference to the power domain. This property is
+ mandatory if the irqpin controller instance is part of a controllable power
+ domain.
+
+
+Example
+-------
+
+ irqpin1: interrupt-controller@e6900004 {
+ compatible = "renesas,intc-irqpin-r8a7740",
+ "renesas,intc-irqpin";
+ #interrupt-cells = <2>;
+ interrupt-controller;
+ reg = <0xe6900004 4>,
+ <0xe6900014 4>,
+ <0xe6900024 1>,
+ <0xe6900044 1>,
+ <0xe6900064 1>;
+ interrupts = <0 149 IRQ_TYPE_LEVEL_HIGH
+ 0 149 IRQ_TYPE_LEVEL_HIGH
+ 0 149 IRQ_TYPE_LEVEL_HIGH
+ 0 149 IRQ_TYPE_LEVEL_HIGH
+ 0 149 IRQ_TYPE_LEVEL_HIGH
+ 0 149 IRQ_TYPE_LEVEL_HIGH
+ 0 149 IRQ_TYPE_LEVEL_HIGH
+ 0 149 IRQ_TYPE_LEVEL_HIGH>;
+ clocks = <&mstp2_clks R8A7740_CLK_INTCA>;
+ power-domains = <&pd_a4s>;
+ };