tty: n_gsm: fix encoding of control signal octet bit DV
authordaniel.starke@siemens.com <daniel.starke@siemens.com>
Fri, 18 Feb 2022 07:31:17 +0000 (23:31 -0800)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 2 Mar 2022 10:33:59 +0000 (11:33 +0100)
commit 737b0ef3be6b319d6c1fd64193d1603311969326 upstream.

n_gsm is based on the 3GPP 07.010 and its newer version is the 3GPP 27.010.
See https://portal.3gpp.org/desktopmodules/Specifications/SpecificationDetails.aspx?specificationId=1516
The changes from 07.010 to 27.010 are non-functional. Therefore, I refer to
the newer 27.010 here. Chapter 5.4.6.3.7 describes the encoding of the
control signal octet used by the MSC (modem status command). The same
encoding is also used in convergence layer type 2 as described in chapter
5.5.2. Table 7 and 24 both require the DV (data valid) bit to be set 1 for
outgoing control signal octets sent by the DTE (data terminal equipment),
i.e. for the initiator side.
Currently, the DV bit is only set if CD (carrier detect) is on, regardless
of the side.

This patch fixes this behavior by setting the DV bit on the initiator side
unconditionally.

Fixes: e1eaea46bb40 ("tty: n_gsm line discipline")
Cc: stable@vger.kernel.org
Signed-off-by: Daniel Starke <daniel.starke@siemens.com>
Link: https://lore.kernel.org/r/20220218073123.2121-1-daniel.starke@siemens.com
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/tty/n_gsm.c

index 52a43922b4fea4da2ffce2961c4ac58880369e5c..a81a5c426966c86f8b30ceaead26358a26513a0f 100644 (file)
@@ -440,7 +440,7 @@ static u8 gsm_encode_modem(const struct gsm_dlci *dlci)
                modembits |= MDM_RTR;
        if (dlci->modem_tx & TIOCM_RI)
                modembits |= MDM_IC;
-       if (dlci->modem_tx & TIOCM_CD)
+       if (dlci->modem_tx & TIOCM_CD || dlci->gsm->initiator)
                modembits |= MDM_DV;
        return modembits;
 }