MLXSW_ITEM32(cmd_mbox, config_profile, flood_mode, 0x30, 0, 2);
+/* cmd_mbox_config_profile_max_fid_flood_tables
+ * Maximum number of per-FID flooding tables.
+ *
+ * Note: This flooding tables cover special FIDs only (vFIDs), starting at
+ * FID value 4K and higher.
+ */
+MLXSW_ITEM32(cmd_mbox, config_profile, max_fid_flood_tables, 0x38, 24, 4);
+
+/* cmd_mbox_config_profile_fid_flood_table_size
+ * The size (number of entries) of each per-FID table.
+ */
+MLXSW_ITEM32(cmd_mbox, config_profile, fid_flood_table_size, 0x38, 0, 16);
+
/* cmd_mbox_config_profile_max_ib_mc
* Maximum number of multicast FDB records for InfiniBand
* FDB (in 512 chunks) per InfiniBand switch partition.
mbox, profile->max_flood_tables);
mlxsw_cmd_mbox_config_profile_max_vid_flood_tables_set(
mbox, profile->max_vid_flood_tables);
+ mlxsw_cmd_mbox_config_profile_max_fid_flood_tables_set(
+ mbox, profile->max_fid_flood_tables);
+ mlxsw_cmd_mbox_config_profile_fid_flood_table_size_set(
+ mbox, profile->fid_flood_table_size);
}
if (profile->used_flood_mode) {
mlxsw_cmd_mbox_config_profile_set_flood_mode_set(