commit
a70ffcac741d31a406c1d2b832ae43d658e7e1cf upstream.
When a thread in a multi-threaded application hits a machine check because
of an uncorrectable error in memory - we want to send the SIGBUS with
si.si_code = BUS_MCEERR_AR to that thread. Currently we fail to do that
if the active thread is not the primary thread in the process.
collect_procs() just finds primary threads and this test:
if ((flags & MF_ACTION_REQUIRED) && t == current) {
will see that the thread we found isn't the current thread and so send a
si.si_code = BUS_MCEERR_AO to the primary (and nothing to the active
thread at this time).
We can fix this by checking whether "current" shares the same mm with the
process that collect_procs() said owned the page. If so, we send the
SIGBUS to current (with code BUS_MCEERR_AR).
Signed-off-by: Tony Luck <tony.luck@intel.com>
Signed-off-by: Naoya Horiguchi <n-horiguchi@ah.jp.nec.com>
Reported-by: Otto Bruggeman <otto.g.bruggeman@intel.com>
Cc: Andi Kleen <andi@firstfloor.org>
Cc: Borislav Petkov <bp@suse.de>
Cc: Chen Gong <gong.chen@linux.jf.intel.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
#endif
si.si_addr_lsb = compound_trans_order(compound_head(page)) + PAGE_SHIFT;
- if ((flags & MF_ACTION_REQUIRED) && t == current) {
+ if ((flags & MF_ACTION_REQUIRED) && t->mm == current->mm) {
si.si_code = BUS_MCEERR_AR;
- ret = force_sig_info(SIGBUS, &si, t);
+ ret = force_sig_info(SIGBUS, &si, current);
} else {
/*
* Don't use force here, it's convenient if the signal