Currently, POWER and BYPASS bits are set up in a single write to pllv3
register. This causes problem occasionally from the IPU/HDMI testing.
Let's follow FSL BSP code to set up POWER bit, relock, and then BYPASS
sequentially.
Signed-off-by: Shawn Guo <shawn.guo@linaro.org>
{
struct clk_pllv3 *pll = to_clk_pllv3(hw);
u32 val;
+ int ret;
val = readl_relaxed(pll->base);
- val &= ~BM_PLL_BYPASS;
if (pll->powerup_set)
val |= BM_PLL_POWER;
else
val &= ~BM_PLL_POWER;
writel_relaxed(val, pll->base);
- return clk_pllv3_wait_lock(pll);
+ ret = clk_pllv3_wait_lock(pll);
+ if (ret)
+ return ret;
+
+ val = readl_relaxed(pll->base);
+ val &= ~BM_PLL_BYPASS;
+ writel_relaxed(val, pll->base);
+
+ return 0;
}
static void clk_pllv3_unprepare(struct clk_hw *hw)