Ruslan reported that f2fs hangs with an infinite loop in f2fs_sync_file():
while (sync_node_pages(sbi, inode->i_ino, &wbc) == 0)
f2fs_write_inode(inode, NULL);
The reason was revealed that the cold flag is not set even thought this inode is
a normal file. Therefore, sync_node_pages() skips to write node blocks since it
only writes cold node blocks.
The cold flag is stored to the node_footer in node block, and whenever a new
node page is allocated, it is set according to its file type, file or directory.
But, after sudden-power-off, when recovering the inode page, f2fs doesn't recover
its cold flag.
So, let's assign the cold flag in more right places.
One more thing:
If f2fs_write_inode() returns an error due to whatever situations, there would
be no dirty node pages so that sync_node_pages() returns zero.
(i.e., zero means nothing was written.)
Reported-by: Ruslan N. Marchenko <me@ruff.mobi>
Signed-off-by: Jaegeuk Kim <jaegeuk.kim@samsung.com>
#include <linux/fs.h>
#include <linux/f2fs_fs.h>
#include "f2fs.h"
+#include "node.h"
#include "acl.h"
static unsigned long dir_blocks(struct inode *inode)
ipage = get_node_page(F2FS_SB(dir->i_sb), inode->i_ino);
if (IS_ERR(ipage))
return PTR_ERR(ipage);
+ set_cold_node(inode, ipage);
init_dent_inode(dentry, ipage);
f2fs_put_page(ipage, 1);
}
if (need_to_sync_dir(sbi, inode))
need_cp = true;
- f2fs_write_inode(inode, NULL);
-
if (need_cp) {
/* all the dirty node pages should be flushed for POR */
ret = f2fs_sync_fs(inode->i_sb, 1);
clear_inode_flag(F2FS_I(inode), FI_NEED_CP);
} else {
- while (sync_node_pages(sbi, inode->i_ino, &wbc) == 0)
- f2fs_write_inode(inode, NULL);
+ /* if there is no written node page, write its inode page */
+ while (!sync_node_pages(sbi, inode->i_ino, &wbc)) {
+ ret = f2fs_write_inode(inode, NULL);
+ if (ret)
+ goto out;
+ }
filemap_fdatawait_range(sbi->node_inode->i_mapping,
0, LONG_MAX);
}
ri->i_flags = cpu_to_le32(F2FS_I(inode)->i_flags);
ri->i_pino = cpu_to_le32(F2FS_I(inode)->i_pino);
ri->i_generation = cpu_to_le32(inode->i_generation);
+ set_cold_node(inode, node_page);
set_page_dirty(node_page);
}
goto fail;
}
set_node_addr(sbi, &new_ni, NEW_ADDR);
+ set_cold_node(dn->inode, page);
dn->node_page = page;
sync_inode_page(dn);
set_page_dirty(page);
- set_cold_node(dn->inode, page);
if (ofs == 0)
inc_valid_inode_count(sbi);