#define ORION_SPI_DATA_OUT_REG 0x08
#define ORION_SPI_DATA_IN_REG 0x0c
#define ORION_SPI_INT_CAUSE_REG 0x10
+#define ORION_SPI_TIMING_PARAMS_REG 0x18
+
+#define ORION_SPI_TMISO_SAMPLE_MASK (0x3 << 6)
+#define ORION_SPI_TMISO_SAMPLE_1 (1 << 6)
+#define ORION_SPI_TMISO_SAMPLE_2 (2 << 6)
#define ORION_SPI_MODE_CPOL (1 << 11)
#define ORION_SPI_MODE_CPHA (1 << 12)
unsigned int min_divisor;
unsigned int max_divisor;
u32 prescale_mask;
+ bool is_errata_50mhz_ac;
};
struct orion_spi {
writel(reg, spi_reg(orion_spi, ORION_SPI_IF_CONFIG_REG));
}
+static void
+orion_spi_50mhz_ac_timing_erratum(struct spi_device *spi, unsigned int speed)
+{
+ u32 reg;
+ struct orion_spi *orion_spi;
+
+ orion_spi = spi_master_get_devdata(spi->master);
+
+ /*
+ * Erratum description: (Erratum NO. FE-9144572) The device
+ * SPI interface supports frequencies of up to 50 MHz.
+ * However, due to this erratum, when the device core clock is
+ * 250 MHz and the SPI interfaces is configured for 50MHz SPI
+ * clock and CPOL=CPHA=1 there might occur data corruption on
+ * reads from the SPI device.
+ * Erratum Workaround:
+ * Work in one of the following configurations:
+ * 1. Set CPOL=CPHA=0 in "SPI Interface Configuration
+ * Register".
+ * 2. Set TMISO_SAMPLE value to 0x2 in "SPI Timing Parameters 1
+ * Register" before setting the interface.
+ */
+ reg = readl(spi_reg(orion_spi, ORION_SPI_TIMING_PARAMS_REG));
+ reg &= ~ORION_SPI_TMISO_SAMPLE_MASK;
+
+ if (clk_get_rate(orion_spi->clk) == 250000000 &&
+ speed == 50000000 && spi->mode & SPI_CPOL &&
+ spi->mode & SPI_CPHA)
+ reg |= ORION_SPI_TMISO_SAMPLE_2;
+ else
+ reg |= ORION_SPI_TMISO_SAMPLE_1; /* This is the default value */
+
+ writel(reg, spi_reg(orion_spi, ORION_SPI_TIMING_PARAMS_REG));
+}
+
/*
* called only when no transfer is active on the bus
*/
orion_spi_mode_set(spi);
+ if (orion_spi->devdata->is_errata_50mhz_ac)
+ orion_spi_50mhz_ac_timing_erratum(spi, speed);
+
rc = orion_spi_baudrate_set(spi, speed);
if (rc)
return rc;
.prescale_mask = ARMADA_SPI_CLK_PRESCALE_MASK,
};
+static const struct orion_spi_dev armada_380_spi_dev_data = {
+ .typ = ARMADA_SPI,
+ .max_hz = 50000000,
+ .max_divisor = 1920,
+ .prescale_mask = ARMADA_SPI_CLK_PRESCALE_MASK,
+ .is_errata_50mhz_ac = true,
+};
+
static const struct of_device_id orion_spi_of_match_table[] = {
{
.compatible = "marvell,orion-spi",
},
{
.compatible = "marvell,armada-380-spi",
- .data = &armada_xp_spi_dev_data,
+ .data = &armada_380_spi_dev_data,
},
{
.compatible = "marvell,armada-390-spi",