Both wpa_supplicant and mac80211 have and inactivity timer. By default
wpa_supplicant will be timed out in 5 minutes and mac80211's it is 30
minutes. If wpa_supplicant uses a longer timer than mac80211, it will
get unexpected disconnection by mac80211.
Using 0xffffffff instead as the configured value could solve this w/o
changing the code, but due to integer overflow in the expression used
this doesn't work. The expression is:
(current jiffies) > (frame Rx jiffies + NL80211_MESHCONF_PLINK_TIMEOUT * 250)
On 32bit system, the right side would overflow and be a very small
value if NL80211_MESHCONF_PLINK_TIMEOUT is sufficiently large,
causing unexpectedly early disconnections.
Instead allow disabling the inactivity timer to avoid this situation,
by passing the (previously invalid and useless) value 0.
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
[reword/rewrap commit log]
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
*
* @NL80211_MESHCONF_PLINK_TIMEOUT: If no tx activity is seen from a STA we've
* established peering with for longer than this time (in seconds), then
- * remove it from the STA's list of peers. Default is 30 minutes.
+ * remove it from the STA's list of peers. You may set this to 0 to disable
+ * the removal of the STA. Default is 30 minutes.
*
* @__NL80211_MESHCONF_ATTR_AFTER_LAST: internal use
*/
struct ieee80211_if_mesh *ifmsh = &sdata->u.mesh;
u32 changed;
- ieee80211_sta_expire(sdata, ifmsh->mshcfg.plink_timeout * HZ);
+ if (ifmsh->mshcfg.plink_timeout > 0)
+ ieee80211_sta_expire(sdata, ifmsh->mshcfg.plink_timeout * HZ);
mesh_path_expire(sdata);
changed = mesh_accept_plinks_update(sdata);
FILL_IN_MESH_PARAM_IF_SET(tb, cfg, dot11MeshAwakeWindowDuration,
0, 65535, mask,
NL80211_MESHCONF_AWAKE_WINDOW, nla_get_u16);
- FILL_IN_MESH_PARAM_IF_SET(tb, cfg, plink_timeout, 1, 0xffffffff,
+ FILL_IN_MESH_PARAM_IF_SET(tb, cfg, plink_timeout, 0, 0xffffffff,
mask, NL80211_MESHCONF_PLINK_TIMEOUT,
nla_get_u32);
if (mask_out)