staging: comedi: pcl711: handle cmd->stop_src and stop_arg
authorIan Abbott <abbotti@mev.co.uk>
Thu, 26 Sep 2013 09:16:38 +0000 (10:16 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 26 Sep 2013 16:34:45 +0000 (09:34 -0700)
The interrupt handler used to support asynchronous commands on the AI
subdevice currently marks the command as finished (setting the "end of
acquisition" event flag and returning to software-triggered acquisition
mode) once it has decremented `devpriv->ntrig` to 0.  However, nothing
sets `devpriv->ntrig`, as noted in the "FIXME" comment.

If the `stop_src` setting of the asynchronous command is `TRIG_COUNT`,
then the `stop_arg` setting indicates the number of scans to be
performed in the overall acquisition.  (Otherwise, `stop_src` will be
`TRIG_NONE`, meaning the acquisition should run indefinitely until
cancelled.)  When starting the acquisition in `pcl711_ai_cmd()`, set
`devpriv->ntrig` to the number of scans to be performed (`stop_arg`) if
`stop_src` is `TRIG_COUNT`.  In the interrupt handler, don't decrement
`devpriv->ntrig` or handle end of acquision unless `stop_src` is
`TRIG_COUNT`.

Also check for an empty acquisition in `pcl711_ai_cmd()`, i.e. one where
`stop_src` is `TRIG_COUNT` and `stop_arg` is zero and just mark end of
acquisition without actually setting up the interrupts in this case.

Also change the type of the `ntrig` member of the private data structure
to `unsigned int` as it should be (same type as `stop_arg`).

Signed-off-by: Ian Abbott <abbotti@mev.co.uk>
Reviewed-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/staging/comedi/drivers/pcl711.c

index 939a11f4e3c86b210c7c40de68a61947bb25d462..daa78fa63be1a53bacf921fbc8585bf9d28d126c 100644 (file)
@@ -156,7 +156,7 @@ static const struct pcl711_board boardtypes[] = {
 };
 
 struct pcl711_private {
-       int ntrig;
+       unsigned int ntrig;
        unsigned int ao_readback[2];
        unsigned int divisor1;
        unsigned int divisor2;
@@ -213,10 +213,8 @@ static irqreturn_t pcl711_interrupt(int irq, void *d)
 
        outb(PCL711_INT_STAT_CLR, dev->iobase + PCL711_INT_STAT_REG);
 
-       /* FIXME! Nothing else sets ntrig! */
-       if (!(--devpriv->ntrig)) {
+       if (s->async->cmd.stop_src == TRIG_COUNT && !(--devpriv->ntrig)) {
                pcl711_ai_set_mode(dev, PCL711_MODE_SOFTTRIG);
-
                s->async->events |= COMEDI_CB_EOA;
        }
        comedi_event(dev, s);
@@ -367,6 +365,16 @@ static int pcl711_ai_cmd(struct comedi_device *dev, struct comedi_subdevice *s)
 
        pcl711_set_changain(dev, s, cmd->chanlist[0]);
 
+       if (cmd->stop_src == TRIG_COUNT) {
+               if (cmd->stop_arg == 0) {
+                       /* an empty acquisition */
+                       s->async->events |= COMEDI_CB_EOA;
+                       comedi_event(dev, s);
+                       return 0;
+               }
+               devpriv->ntrig = cmd->stop_arg;
+       }
+
        if (cmd->scan_begin_src == TRIG_TIMER) {
                i8254_load(dev->iobase + PCL711_TIMER_BASE, 0,
                           1, devpriv->divisor1, I8254_MODE2 | I8254_BINARY);