clocksource/drivers/armada-370-xp: Make syscore_ops static
authorBen Dooks <ben.dooks@codethink.co.uk>
Thu, 16 Jun 2016 13:47:49 +0000 (15:47 +0200)
committerDaniel Lezcano <daniel.lezcano@linaro.org>
Tue, 28 Jun 2016 08:16:30 +0000 (10:16 +0200)
The driver does not export armada_370_xp_timer_syscore_ops so
make it static to fix the following warning:

drivers/clocksource/time-armada-370-xp.c:249:20: warning: symbol 'armada_370_xp_timer_syscore_ops' was not declared. Should it be static?

Signed-off-by: Ben Dooks <ben.dooks@codethink.co.uk>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Gregory CLEMENT <gregory.clement@free-electrons.com>
drivers/clocksource/time-armada-370-xp.c

index d93ec3c4f139f2bbcf1ada62efaeed9e6062fb66..601dbf744aa51b69275cbb7590a9d175825b1891 100644 (file)
@@ -246,7 +246,7 @@ static void armada_370_xp_timer_resume(void)
        writel(timer0_local_ctrl_reg, local_base + TIMER_CTRL_OFF);
 }
 
-struct syscore_ops armada_370_xp_timer_syscore_ops = {
+static struct syscore_ops armada_370_xp_timer_syscore_ops = {
        .suspend        = armada_370_xp_timer_suspend,
        .resume         = armada_370_xp_timer_resume,
 };