iio: humidity: hdc100x: fix IIO_HUMIDITYRELATIVE channel reporting
authorChris Lesiak <chris.lesiak@licor.com>
Thu, 21 Nov 2019 20:39:42 +0000 (20:39 +0000)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sat, 21 Dec 2019 09:41:52 +0000 (10:41 +0100)
commit 342a6928bd5017edbdae376042d8ad6af3d3b943 upstream.

The IIO_HUMIDITYRELATIVE channel was being incorrectly reported back
as percent when it should have been milli percent. This is via an
incorrect scale value being returned to userspace.

Signed-off-by: Chris Lesiak <chris.lesiak@licor.com>
Acked-by: Matt Ranostay <matt.ranostay@konsulko.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/iio/humidity/hdc100x.c

index e0c9c70c2a4ae6dcc1723abc114ad036511a0c97..c0e2e78c5c62c213152ac1be7cbc959817df334d 100644 (file)
@@ -202,7 +202,7 @@ static int hdc100x_read_raw(struct iio_dev *indio_dev,
                        *val2 = 65536;
                        return IIO_VAL_FRACTIONAL;
                } else {
-                       *val = 100;
+                       *val = 100000;
                        *val2 = 65536;
                        return IIO_VAL_FRACTIONAL;
                }