e1000e: set flow control thresholds properly after enabling/disabling pause
authorBruce Allan <bruce.w.allan@intel.com>
Thu, 19 Nov 2009 12:35:08 +0000 (12:35 +0000)
committerDavid S. Miller <davem@davemloft.net>
Fri, 20 Nov 2009 21:53:24 +0000 (13:53 -0800)
When flow control (pause) parameters were changed via ethtool (i.e. enabled
or disabled), the newly calculated thresholds were not being written to the
device for non-fiber media.

Signed-off-by: Bruce Allan <bruce.w.allan@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/e1000e/ethtool.c

index 1bf4d2a5d34f8b7421839033c7dd4cedb748bc1c..e82638ecae88dbc079adf98089b7c42a0626c4a2 100644 (file)
@@ -327,10 +327,18 @@ static int e1000_set_pauseparam(struct net_device *netdev,
 
                hw->fc.current_mode = hw->fc.requested_mode;
 
-               retval = ((hw->phy.media_type == e1000_media_type_fiber) ?
-                         hw->mac.ops.setup_link(hw) : e1000e_force_mac_fc(hw));
+               if (hw->phy.media_type == e1000_media_type_fiber) {
+                       retval = hw->mac.ops.setup_link(hw);
+                       /* implicit goto out */
+               } else {
+                       retval = e1000e_force_mac_fc(hw);
+                       if (retval)
+                               goto out;
+                       e1000e_set_fc_watermarks(hw);
+               }
        }
 
+out:
        clear_bit(__E1000_RESETTING, &adapter->state);
        return retval;
 }