P1020, P1021, P1022, P1023 when the lbc get error, the error
interrupt will be triggered. The corresponding interrupt is
internal IRQ0. So system have to process the lbc IRQ0 interrupt.
The corresponding lbc general interrupt is internal IRQ3.
Signed-off-by: Wang Dongsheng <dongsheng.wang@freescale.com>
[scottwood@freescale.com: bracketed individual list elements]
Signed-off-by: Scott Wood <scottwood@freescale.com>
#address-cells = <2>;
#size-cells = <1>;
compatible = "fsl,p1020-elbc", "fsl,elbc", "simple-bus";
- interrupts = <19 2 0 0>;
+ interrupts = <19 2 0 0>,
+ <16 2 0 0>;
};
/* controller at 0x9000 */
#address-cells = <2>;
#size-cells = <1>;
compatible = "fsl,p1021-elbc", "fsl,elbc", "simple-bus";
- interrupts = <19 2 0 0>;
+ interrupts = <19 2 0 0>,
+ <16 2 0 0>;
};
/* controller at 0x9000 */
* pin muxing when the DIU is enabled.
*/
compatible = "fsl,p1022-elbc", "fsl,elbc";
- interrupts = <19 2 0 0>;
+ interrupts = <19 2 0 0>,
+ <16 2 0 0>;
};
/* controller at 0x9000 */
#address-cells = <2>;
#size-cells = <1>;
compatible = "fsl,p1023-elbc", "fsl,elbc", "simple-bus";
- interrupts = <19 2 0 0>;
+ interrupts = <19 2 0 0>,
+ <16 2 0 0>;
};
/* controller at 0xa000 */