Don't need to start I/O twice (once without i_mutex and one within).
Also make sure that even if the userspace filesystem doesn't support FSYNC
we do all the steps other than sending the message.
Signed-off-by: Miklos Szeredi <mszeredi@suse.cz>
if (is_bad_inode(inode))
return -EIO;
- err = filemap_write_and_wait_range(inode->i_mapping, start, end);
- if (err)
- return err;
-
- if ((!isdir && fc->no_fsync) || (isdir && fc->no_fsyncdir))
- return 0;
-
mutex_lock(&inode->i_mutex);
/*
* wait for all outstanding writes, before sending the FSYNC
* request.
*/
- err = write_inode_now(inode, 0);
+ err = filemap_write_and_wait_range(inode->i_mapping, start, end);
if (err)
goto out;
if (err)
goto out;
}
+ if ((!isdir && fc->no_fsync) || (isdir && fc->no_fsyncdir))
+ goto out;
req = fuse_get_req_nopages(fc);
if (IS_ERR(req)) {