goto out;
}
if (new_value < 0) {
- pr_err("%s: Invalid arp_interval value %d not in range 1-%d; rejected.\n",
+ pr_err("%s: Invalid arp_interval value %d not in range 0-%d; rejected.\n",
bond->dev->name, new_value, INT_MAX);
ret = -EINVAL;
goto out;
pr_info("%s: Setting ARP monitoring interval to %d.\n",
bond->dev->name, new_value);
bond->params.arp_interval = new_value;
- if (bond->params.miimon) {
- pr_info("%s: ARP monitoring cannot be used with MII monitoring. %s Disabling MII monitoring.\n",
- bond->dev->name, bond->dev->name);
- bond->params.miimon = 0;
- }
- if (!bond->params.arp_targets[0]) {
- pr_info("%s: ARP monitoring has been set up, but no ARP targets have been specified.\n",
- bond->dev->name);
+ if (new_value) {
+ if (bond->params.miimon) {
+ pr_info("%s: ARP monitoring cannot be used with MII monitoring. %s Disabling MII monitoring.\n",
+ bond->dev->name, bond->dev->name);
+ bond->params.miimon = 0;
+ }
+ if (!bond->params.arp_targets[0])
+ pr_info("%s: ARP monitoring has been set up, but no ARP targets have been specified.\n",
+ bond->dev->name);
}
if (bond->dev->flags & IFF_UP) {
/* If the interface is up, we may need to fire off
* timer will get fired off when the open function
* is called.
*/
- cancel_delayed_work_sync(&bond->mii_work);
- queue_delayed_work(bond->wq, &bond->arp_work, 0);
+ if (!new_value) {
+ cancel_delayed_work_sync(&bond->arp_work);
+ } else {
+ cancel_delayed_work_sync(&bond->mii_work);
+ queue_delayed_work(bond->wq, &bond->arp_work, 0);
+ }
}
-
out:
rtnl_unlock();
return ret;
}
if (new_value < 0) {
pr_err("%s: Invalid down delay value %d not in range %d-%d; rejected.\n",
- bond->dev->name, new_value, 1, INT_MAX);
+ bond->dev->name, new_value, 0, INT_MAX);
ret = -EINVAL;
goto out;
} else {
goto out;
}
if (new_value < 0) {
- pr_err("%s: Invalid down delay value %d not in range %d-%d; rejected.\n",
- bond->dev->name, new_value, 1, INT_MAX);
+ pr_err("%s: Invalid up delay value %d not in range %d-%d; rejected.\n",
+ bond->dev->name, new_value, 0, INT_MAX);
ret = -EINVAL;
goto out;
} else {
}
if (new_value < 0) {
pr_err("%s: Invalid miimon value %d not in range %d-%d; rejected.\n",
- bond->dev->name, new_value, 1, INT_MAX);
+ bond->dev->name, new_value, 0, INT_MAX);
ret = -EINVAL;
goto out;
- } else {
- pr_info("%s: Setting MII monitoring interval to %d.\n",
- bond->dev->name, new_value);
- bond->params.miimon = new_value;
- if (bond->params.updelay)
- pr_info("%s: Note: Updating updelay (to %d) since it is a multiple of the miimon value.\n",
- bond->dev->name,
- bond->params.updelay * bond->params.miimon);
- if (bond->params.downdelay)
- pr_info("%s: Note: Updating downdelay (to %d) since it is a multiple of the miimon value.\n",
- bond->dev->name,
- bond->params.downdelay * bond->params.miimon);
- if (bond->params.arp_interval) {
- pr_info("%s: MII monitoring cannot be used with ARP monitoring. Disabling ARP monitoring...\n",
- bond->dev->name);
- bond->params.arp_interval = 0;
- if (bond->params.arp_validate) {
- bond->params.arp_validate =
- BOND_ARP_VALIDATE_NONE;
- }
- }
-
- if (bond->dev->flags & IFF_UP) {
- /* If the interface is up, we may need to fire off
- * the MII timer. If the interface is down, the
- * timer will get fired off when the open function
- * is called.
- */
+ }
+ pr_info("%s: Setting MII monitoring interval to %d.\n",
+ bond->dev->name, new_value);
+ bond->params.miimon = new_value;
+ if (bond->params.updelay)
+ pr_info("%s: Note: Updating updelay (to %d) since it is a multiple of the miimon value.\n",
+ bond->dev->name,
+ bond->params.updelay * bond->params.miimon);
+ if (bond->params.downdelay)
+ pr_info("%s: Note: Updating downdelay (to %d) since it is a multiple of the miimon value.\n",
+ bond->dev->name,
+ bond->params.downdelay * bond->params.miimon);
+ if (new_value && bond->params.arp_interval) {
+ pr_info("%s: MII monitoring cannot be used with ARP monitoring. Disabling ARP monitoring...\n",
+ bond->dev->name);
+ bond->params.arp_interval = 0;
+ if (bond->params.arp_validate)
+ bond->params.arp_validate = BOND_ARP_VALIDATE_NONE;
+ }
+ if (bond->dev->flags & IFF_UP) {
+ /* If the interface is up, we may need to fire off
+ * the MII timer. If the interface is down, the
+ * timer will get fired off when the open function
+ * is called.
+ */
+ if (!new_value) {
+ cancel_delayed_work_sync(&bond->mii_work);
+ } else {
cancel_delayed_work_sync(&bond->arp_work);
queue_delayed_work(bond->wq, &bond->mii_work, 0);
}