CLK_PCLK_MONOTONIC_CNT clock had a wrong register assigned to it.
The correct register is ENABLE_PCLK_MIF_SECURE_MONOTONIC_CNT.
Signed-off-by: Jonghwa Lee <jonghwa3.lee@samsung.com>
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Reviewed-by: Krzysztof Kozlowski <k.kozlowski.k@gmail.com>
Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
/* ENABLE_PCLK_MIF_SECURE_MONOTONIC_CNT */
GATE(CLK_PCLK_MONOTONIC_CNT, "pclk_monotonic_cnt", "div_aclk_mif_133",
- ENABLE_PCLK_MIF_SECURE_RTC, 0, 0, 0),
+ ENABLE_PCLK_MIF_SECURE_MONOTONIC_CNT, 0, 0, 0),
/* ENABLE_PCLK_MIF_SECURE_RTC */
GATE(CLK_PCLK_RTC, "pclk_rtc", "div_aclk_mif_133",