clk: exynos5433: Fix CLK_PCLK_MONOTONIC_CNT clk register assignment
authorJonghwa Lee <jonghwa3.lee@samsung.com>
Mon, 27 Apr 2015 11:36:30 +0000 (20:36 +0900)
committerSylwester Nawrocki <s.nawrocki@samsung.com>
Wed, 29 Apr 2015 12:11:09 +0000 (14:11 +0200)
CLK_PCLK_MONOTONIC_CNT clock had a wrong register assigned to it.
The correct register is ENABLE_PCLK_MIF_SECURE_MONOTONIC_CNT.

Signed-off-by: Jonghwa Lee <jonghwa3.lee@samsung.com>
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Reviewed-by: Krzysztof Kozlowski <k.kozlowski.k@gmail.com>
Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
drivers/clk/samsung/clk-exynos5433.c

index 543f9c7707a7fbff0b69177effd89091b7242b8c..b1a546e402aa1893b3517f0ce664dfc044db2c9e 100644 (file)
@@ -1490,7 +1490,7 @@ static struct samsung_gate_clock mif_gate_clks[] __initdata = {
 
        /* ENABLE_PCLK_MIF_SECURE_MONOTONIC_CNT */
        GATE(CLK_PCLK_MONOTONIC_CNT, "pclk_monotonic_cnt", "div_aclk_mif_133",
-                       ENABLE_PCLK_MIF_SECURE_RTC, 0, 0, 0),
+                       ENABLE_PCLK_MIF_SECURE_MONOTONIC_CNT, 0, 0, 0),
 
        /* ENABLE_PCLK_MIF_SECURE_RTC */
        GATE(CLK_PCLK_RTC, "pclk_rtc", "div_aclk_mif_133",