igb: reset the PHY before reading the PHY ID
authorAaron Sierra <asierra@xes-inc.com>
Tue, 29 Nov 2016 16:03:56 +0000 (10:03 -0600)
committerJeff Kirsher <jeffrey.t.kirsher@intel.com>
Fri, 6 Jan 2017 10:18:51 +0000 (02:18 -0800)
Several people have reported firmware leaving the I210/I211 PHY's page
select register set to something other than the default of zero. This
causes the first accesses, PHY_IDx register reads, to access something
else, resulting in device probe failure:

    igb: Intel(R) Gigabit Ethernet Network Driver - version 5.4.0-k
    igb: Copyright (c) 2007-2014 Intel Corporation.
    igb: probe of 0000:01:00.0 failed with error -2

This problem began for them after a previous patch I submitted was
applied:

    commit 2a3cdead8b408351fa1e3079b220fa331480ffbc
    Author: Aaron Sierra <asierra@xes-inc.com>
    Date:   Tue Nov 3 12:37:09 2015 -0600

        igb: Remove GS40G specific defines/functions

I personally experienced this problem after attempting to PXE boot from
I210 devices using this firmware:

    Intel(R) Boot Agent GE v1.5.78
    Copyright (C) 1997-2014, Intel Corporation

Resetting the PHY before reading from it, ensures the page select
register is in its default state and doesn't make assumptions about
the PHY's register set before the PHY has been probed.

Cc: Matwey V. Kornilov <matwey@sai.msu.ru>
Cc: Chris Arges <carges@vectranetworks.com>
Cc: Jochen Henneberg <jh@henneberg-systemdesign.com>
Signed-off-by: Aaron Sierra <asierra@xes-inc.com>
Tested-by: Matwey V. Kornilov <matwey@sai.msu.ru>
Tested-by: Chris J Arges <christopherarges@gmail.com>
Tested-by: Aaron Brown <aaron.f.brown@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
drivers/net/ethernet/intel/igb/e1000_82575.c

index a61447fd778eb579ef0b31d1a0d4c33a9e5386ee..ee443985581fe2be3c60bb0bc23f7cfb40ac652e 100644 (file)
@@ -245,6 +245,17 @@ static s32 igb_init_phy_params_82575(struct e1000_hw *hw)
        hw->bus.func = (rd32(E1000_STATUS) & E1000_STATUS_FUNC_MASK) >>
                        E1000_STATUS_FUNC_SHIFT;
 
+       /* Make sure the PHY is in a good state. Several people have reported
+        * firmware leaving the PHY's page select register set to something
+        * other than the default of zero, which causes the PHY ID read to
+        * access something other than the intended register.
+        */
+       ret_val = hw->phy.ops.reset(hw);
+       if (ret_val) {
+               hw_dbg("Error resetting the PHY.\n");
+               goto out;
+       }
+
        /* Set phy->phy_addr and phy->id. */
        ret_val = igb_get_phy_id_82575(hw);
        if (ret_val)