The 'Word Clock Status' control on Delta 1010LT checks the CS8427
error register too strictly and almost always returns 1 (unlocked).
It should check only the lock status bit.
Signed-off-by: Takashi Iwai <tiwai@suse.de>
Signed-off-by: Jaroslav Kysela <perex@perex.cz>
if (snd_i2c_sendbytes(ice->cs8427, ®, 1) != 1)
snd_printk(KERN_ERR "unable to send register 0x%x byte to CS8427\n", reg);
snd_i2c_readbytes(ice->cs8427, ®, 1);
- ucontrol->value.integer.value[0] = (reg ? 1 : 0);
+ ucontrol->value.integer.value[0] = (reg & CS8427_UNLOCK) ? 1 : 0;
return 0;
}