The RDU2 has a Marvell
88E6352 switch. Both the FEC and the i210
Ethernet interfaces are connected to the switch. Make the FEC the DSA
"CPU" port, and the i210 as a regular port on the switch.
Signed-off-by: Andrew Lunn <andrew@lunn.ch>
Tested-by: Chris Healy <cphealy@gmail.com>
Reviewed-by: Fabio Estevam <fabio.estevam@nxp.com>
Signed-off-by: Shawn Guo <shawnguo@kernel.org>
phy-reset-duration = <100>;
phy-supply = <®_3p3v>;
status = "okay";
+
+ mdio {
+ #address-cells = <1>;
+ #size-cells = <0>;
+ status = "okay";
+
+ switch@0 {
+ compatible = "marvell,mv88e6085";
+ #address-cells = <1>;
+ #size-cells = <0>;
+ reg = <0>;
+ dsa,member = <0 0>;
+
+ ports {
+ #address-cells = <1>;
+ #size-cells = <0>;
+
+ port@0 {
+ reg = <0>;
+ label = "gigabit_proc";
+ };
+
+ port@1 {
+ reg = <1>;
+ label = "netaux";
+ };
+
+ port@2 {
+ reg = <2>;
+ label = "cpu";
+ ethernet = <&fec>;
+
+ fixed-link {
+ speed = <100>;
+ full-duplex;
+ };
+ };
+
+ port@3 {
+ reg = <3>;
+ label = "netright";
+ };
+
+ port@4 {
+ reg = <4>;
+ label = "netleft";
+ };
+ };
+ };
+ };
};
&usbh1 {