regulator: fix kernel-doc warnings
authorRandy Dunlap <randy.dunlap@oracle.com>
Thu, 8 Jan 2009 19:50:23 +0000 (11:50 -0800)
committerLiam Girdwood <lrg@slimlogic.co.uk>
Thu, 8 Jan 2009 20:10:38 +0000 (20:10 +0000)
Fix kernel-doc warnings in regulator/driver.h:

Warning(linux-next-20090108//include/linux/regulator/driver.h:95): Excess struct/union/enum/typedef member 'set_current' description in 'regulator_ops'
Warning(linux-next-20090108//include/linux/regulator/driver.h:95): Excess struct/union/enum/typedef member 'get_current' description in 'regulator_ops'
Warning(linux-next-20090108//include/linux/regulator/driver.h:124): No description found for parameter 'irq'

Signed-off-by: Randy Dunlap <randy.dunlap@oracle.com>
cc: Liam Girdwood <lrg@slimlogic.co.uk>
cc: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
include/linux/regulator/driver.h

index 84c3737c2d26bfb369dc41254e1c578241667924..2dae05705f13e21b9d3410b6c5dfb494a1b9bab8 100644 (file)
@@ -29,16 +29,12 @@ struct regulator_init_data;
  *
  * @enable: Enable the regulator.
  * @disable: Disable the regulator.
- * @is_enabled: Return 1 if the reguator is enabled, 0 otherwise.
+ * @is_enabled: Return 1 if the regulator is enabled, 0 otherwise.
  *
  * @set_voltage: Set the voltage for the regulator within the range specified.
  *               The driver should select the voltage closest to min_uV.
  * @get_voltage: Return the currently configured voltage for the regulator.
  *
- * @set_current: Set the current for the regulator within the range specified.
- *               The driver should select the current closest to min_uA.
- * @get_current: Return the currently configured current for the regulator.
- *
  * @set_current_limit: Configure a limit for a current-limited regulator.
  * @get_current_limit: Get the limit for a current-limited regulator.
  *
@@ -111,6 +107,7 @@ enum regulator_type {
  * @name: Identifying name for the regulator.
  * @id: Numerical identifier for the regulator.
  * @ops: Regulator operations table.
+ * @irq: Interrupt number for the regulator.
  * @type: Indicates if the regulator is a voltage or current regulator.
  * @owner: Module providing the regulator, used for refcounting.
  */