be2net: Fix endian issue in logical link config command
authorSuresh Reddy <suresh.reddy@broadcom.com>
Thu, 30 Mar 2017 04:58:32 +0000 (00:58 -0400)
committerDavid S. Miller <davem@davemloft.net>
Thu, 30 Mar 2017 22:57:33 +0000 (15:57 -0700)
Use cpu_to_le32() for link_config variable in set_logical_link_config
command as this variable is of type u32.

Signed-off-by: Suresh Reddy <suresh.reddy@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/ethernet/emulex/benet/be_cmds.c

index 30e855004c57592f9ab6c0cea2eb73f63b59b7ca..02dd5246dfae9a99b20f2bb4b2b13185d3239a3c 100644 (file)
@@ -4939,8 +4939,9 @@ static int
 __be_cmd_set_logical_link_config(struct be_adapter *adapter,
                                 int link_state, int version, u8 domain)
 {
-       struct be_mcc_wrb *wrb;
        struct be_cmd_req_set_ll_link *req;
+       struct be_mcc_wrb *wrb;
+       u32 link_config = 0;
        int status;
 
        mutex_lock(&adapter->mcc_lock);
@@ -4962,10 +4963,12 @@ __be_cmd_set_logical_link_config(struct be_adapter *adapter,
 
        if (link_state == IFLA_VF_LINK_STATE_ENABLE ||
            link_state == IFLA_VF_LINK_STATE_AUTO)
-               req->link_config |= PLINK_ENABLE;
+               link_config |= PLINK_ENABLE;
 
        if (link_state == IFLA_VF_LINK_STATE_AUTO)
-               req->link_config |= PLINK_TRACK;
+               link_config |= PLINK_TRACK;
+
+       req->link_config = cpu_to_le32(link_config);
 
        status = be_mcc_notify_wait(adapter);
 err: