A bug in the family-model-stepping matching code caused the presence of
errata to go undetected when OSVW was not used. This causes hangs on
some K8 systems because the E400 workaround is not enabled.
Signed-off-by: Hans Rosenfeld <hans.rosenfeld@amd.com>
LKML-Reference: <
1282141190-930137-1-git-send-email-hans.rosenfeld@amd.com>
Signed-off-by: H. Peter Anvin <hpa@zytor.com>
}
/* OSVW unavailable or ID unknown, match family-model-stepping range */
- ms = (cpu->x86_model << 8) | cpu->x86_mask;
+ ms = (cpu->x86_model << 4) | cpu->x86_mask;
while ((range = *erratum++))
if ((cpu->x86 == AMD_MODEL_RANGE_FAMILY(range)) &&
(ms >= AMD_MODEL_RANGE_START(range)) &&