During the initialization of the TPM TIS driver, the necessary locality has
to be requested earlier in the init-process. Depending on the used TPM
chip, this leads to wrong information. For example: Lenovo X61s with Atmel
TPM:
tpm_tis 00:0a: 1.2 TPM (device-id 0xFFFF, rev-id 255)
But correct is:
tpm_tis 00:0c: 1.2 TPM (device-id 0x3203, rev-id 9)
This short patch fixes this issue.
Signed-off-by: Marcel Selhorst <tpm@selhorst.net>
Cc: Kylene Jo Hall <kjhall@us.ibm.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
goto out_err;
}
+ if (request_locality(chip, 0) != 0) {
+ rc = -ENODEV;
+ goto out_err;
+ }
+
vendor = ioread32(chip->vendor.iobase + TPM_DID_VID(0));
/* Default timeouts */
if (intfcaps & TPM_INTF_DATA_AVAIL_INT)
dev_dbg(dev, "\tData Avail Int Support\n");
- if (request_locality(chip, 0) != 0) {
- rc = -ENODEV;
- goto out_err;
- }
-
/* INTERRUPT Setup */
init_waitqueue_head(&chip->vendor.read_queue);
init_waitqueue_head(&chip->vendor.int_queue);