This value depends on the touch screen.
- pre-charge-time: the touch screen need some time to precharge.
This value depends on the touch screen.
+- average-samples: Number of data samples which are averaged for each read.
+ Valid values 0-4
+ 0 = 1 sample
+ 1 = 4 samples
+ 2 = 8 samples
+ 3 = 16 samples
+ 4 = 32 samples
Example:
tsc: tsc@02040000 {
xnur-gpio = <&gpio1 3 GPIO_ACTIVE_LOW>;
measure-delay-time = <0xfff>;
pre-charge-time = <0xffff>;
+ average-samples = <4>;
status = "okay";
};
/* ADC configuration registers field define */
#define ADC_AIEN (0x1 << 7)
#define ADC_CONV_DISABLE 0x1F
+#define ADC_AVGE (0x1 << 5)
#define ADC_CAL (0x1 << 7)
#define ADC_CALF 0x2
#define ADC_12BIT_MODE (0x2 << 2)
#define ADC_CLK_DIV_8 (0x03 << 5)
#define ADC_SHORT_SAMPLE_MODE (0x0 << 4)
#define ADC_HARDWARE_TRIGGER (0x1 << 13)
+#define ADC_AVGS_SHIFT 14
#define SELECT_CHANNEL_4 0x04
#define SELECT_CHANNEL_1 0x01
#define DISABLE_CONVERSION_INT (0x0 << 7)
int measure_delay_time;
int pre_charge_time;
+ int average_samples;
struct completion completion;
};
adc_cfg = readl(tsc->adc_regs + REG_ADC_CFG);
adc_cfg |= ADC_12BIT_MODE | ADC_IPG_CLK;
adc_cfg |= ADC_CLK_DIV_8 | ADC_SHORT_SAMPLE_MODE;
+ if (tsc->average_samples)
+ adc_cfg |= (tsc->average_samples - 1) << ADC_AVGS_SHIFT;
adc_cfg &= ~ADC_HARDWARE_TRIGGER;
writel(adc_cfg, tsc->adc_regs + REG_ADC_CFG);
/* start ADC calibration */
adc_gc = readl(tsc->adc_regs + REG_ADC_GC);
adc_gc |= ADC_CAL;
+ if (tsc->average_samples)
+ adc_gc |= ADC_AVGE;
writel(adc_gc, tsc->adc_regs + REG_ADC_GC);
timeout = wait_for_completion_timeout
if (err)
tsc->pre_charge_time = 0xfff;
+ err = of_property_read_u32(np, "average-samples",
+ &tsc->average_samples);
+ if (err)
+ tsc->average_samples = 0;
+
+ if (tsc->average_samples > 4) {
+ dev_err(&pdev->dev, "average-samples (%u) must be [0-4]\n",
+ tsc->average_samples);
+ return -EINVAL;
+ }
+
err = input_register_device(tsc->input);
if (err) {
dev_err(&pdev->dev,