The PF driver does not check if the administrator has already set a VF
VLAN via the PF driver before setting the new VLAN. This results in
the following scenario:
A) Administrator sets VF <n> to VLAN 100
B) Administrator sets VF <x> to VLAN 100
C) Administrator sets VF <n> to VLAN 200
D) The VF <n> driver continues to be able to receive traffic on VLAN
100 because the VLVFB pool enable bit for that VF was left set
instead of being cleared as it should be.
This fix ensures that the old VLAN filter for VF <n> is first removed
and the pool bit enable for VF <n> is cleared so that it no longer
receives traffic on VLAN 100.
Signed-off-by: Greg Rose <gregory.v.rose@intel.com>
Tested-by: Sibai Li <sibai.li@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
if ((vf >= adapter->num_vfs) || (vlan > 4095) || (qos > 7))
return -EINVAL;
if (vlan || qos) {
+ if (adapter->vfinfo[vf].pf_vlan)
+ err = ixgbe_set_vf_vlan(adapter, false,
+ adapter->vfinfo[vf].pf_vlan,
+ vf);
+ if (err)
+ goto out;
err = ixgbe_set_vf_vlan(adapter, true, vlan, vf);
if (err)
goto out;