USB: cdc_acm: Fix oops when Droids MuIn LCD is connected
The Droids MuIn LCD operates like a serial remote terminal.
Data received are displayed directly on the LCD. This patch
fixes the kernel null pointer oops when it is plugged in.
Add NO_DATA_INTERFACE quirk to tell the driver that "control"
and "data" interfaces are not separated for this device, which
prevents dereferencing a null pointer in the device probe code.
Signed-off-by: Erik Slagter <erik@slagter.name>
Signed-off-by: Maxin B. John <maxin.john@gmail.com>
Tested-by: Erik Slagter <erik@slagter.name>
Cc: stable <stable@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>