clk: axi-clkgen: Correctly handle nocount bit in recalc_rate()
[ Upstream commit
063578dc5f407f67d149133818efabe457daafda ]
If the nocount bit is set the divider is bypassed and the settings for the
divider count should be ignored and a divider value of 1 should be assumed.
Handle this correctly in the driver recalc_rate() callback.
While the driver sets up the part so that the read back dividers values
yield the correct result the power-on reset settings of the part might not
reflect this and hence calling e.g. clk_get_rate() without prior calls to
clk_set_rate() will yield the wrong result.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
Signed-off-by: Sasha Levin <alexander.levin@microsoft.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>