8250.c: less than 2400 baud fix.
authorChristian Melki <christian.melki@ericsson.se>
Mon, 30 Apr 2012 09:21:26 +0000 (11:21 +0200)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Tue, 1 May 2012 17:40:29 +0000 (13:40 -0400)
commitf9a9111b540fd67db5dab332f4b83d86c90e27b1
tree469a440d5c538c42c835e79c77fd3027971d0587
parentaaa10eb1d0034eccc096f583fe308f0921617598
8250.c: less than 2400 baud fix.

We noticed that we were loosing data at speed less than 2400 baud.
It turned out our (TI16750 compatible) uart with 64 byte outgoing fifo
was truncated to 16 byte (bit 5 sets fifo len) when modifying the fcr
reg.
The input code still fills the buffer with 64 bytes if I remember
correctly and thus data is lost.
Our fix was to remove whiping of the fcr content and just add the
TRIGGER_1 which we want for latency.
I can't see why this would not work on less than 2400 always, for all
uarts ...
Otherwise one would have to make sure the filling of the fifo re-checks
the current state of available fifo size (urrk).

Signed-off-by: Christian Melki <christian.melki@ericsson.se>
Cc: stable <stable@vger.kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/tty/serial/8250/8250.c