watchdog: dw: RMW the control register
[ Upstream commit
a81abbb412341e9e3b2d42ed7d310cf71fbb84a8 ]
RK3399 has rst_pulse_length in CONTROL_REG[4:2], determining the length
of pulse to issue for system reset. We shouldn't clobber this value,
because that might make the system reset ineffective. On RK3399, we're
seeing that a value of 000b (meaning 2 cycles) yields an unreliable
(partial?) reset, and so we only fully reset after the watchdog fires a
second time. If we retain the system default (010b, or 8 clock cycles),
then the watchdog reset is much more reliable.
Read-modify-write retains the system value and improves reset
reliability.
It seems we were intentionally clobbering the response mode previously,
to ensure we performed a system reset (we don't support an interrupt
notification), so retain that explicitly.
Signed-off-by: Brian Norris <briannorris@chromium.org>
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Wim Van Sebroeck <wim@iguana.be>
Signed-off-by: Sasha Levin <alexander.levin@microsoft.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>