rtc: s35390a: implement reset routine as suggested by the reference
authorUwe Kleine-König <uwe@kleine-koenig.org>
Sat, 2 Jul 2016 15:28:09 +0000 (17:28 +0200)
committerWilly Tarreau <w@1wt.eu>
Tue, 20 Jun 2017 12:04:40 +0000 (14:04 +0200)
commitdf4be7e66b1e801140e65b275bcc67809610ad7a
tree2f2d3d64ba8e35d46f099f2d8ca3ec6863a787d1
parent231b0f80d19c96a2083fc735a116882e8db92df5
rtc: s35390a: implement reset routine as suggested by the reference

commit 8e6583f1b5d1f5f129b873f1428b7e414263d847 upstream.

There were two deviations from the reference manual: you have to wait
half a second when POC is active and you might have to repeat
initialization when POC or BLD are still set after the sequence.

Note however that as POC and BLD are cleared by read the driver might
not be able to detect that a reset is necessary. I don't have a good
idea how to fix this.

Additionally report the value read from STATUS1 to the caller. This
prepares the next patch.

Signed-off-by: Uwe Kleine-König <uwe@kleine-koenig.org>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
Signed-off-by: Willy Tarreau <w@1wt.eu>
drivers/rtc/rtc-s35390a.c