sfc: Use extended MC_CMD_SENSOR_INFO and MC_CMD_READ_SENSORS
authorBen Hutchings <bhutchings@solarflare.com>
Thu, 8 Aug 2013 10:14:20 +0000 (11:14 +0100)
committerBen Hutchings <bhutchings@solarflare.com>
Tue, 27 Aug 2013 21:29:56 +0000 (22:29 +0100)
commitd4fbdcfe93928fbcb7374ea490e41f7b69d95380
tree153ce5ee26d6d128d0d5a0d157dda322ac2fc0e5
parent8c4e720f181f251948c52913c74a86f68aed9c50
sfc: Use extended MC_CMD_SENSOR_INFO and MC_CMD_READ_SENSORS

We need to use extended requests to read and get metadata for sensors
numbered > 31.

Signed-off-by: Ben Hutchings <bhutchings@solarflare.com>
drivers/net/ethernet/sfc/mcdi_mon.c