Sensor: (1/1) fix issue - CapSensor calibration value is incorrect first time
authorlitao2 <litao2@huaqin.com>
Sat, 12 Jan 2019 06:47:43 +0000 (14:47 +0800)
committerxiest1 <xiest1@lenovo.com>
Tue, 5 Nov 2019 09:30:35 +0000 (17:30 +0800)
commitcc08192e15c092905a1d65937c0876e4335e05fc
treeac09e0bd666ce0120aed2f61004b237b7c109504
parent4a8944e82ea77e7b3b58d573cf2dba3758552be9
Sensor: (1/1) fix issue - CapSensor calibration value is incorrect first time

After writing calibration command to CMD register, user must wait 1.5 seconds
at least for calibration complete.

Bug:(CR)

Workaround:no

Change-Id: I8af3a56bce69b3d5b74d4fefd41cdddb3331451f
Signed-off-by: litao2 <litao2@huaqin.com>
drivers/input/misc/sx933x_sar.c