i2c: omap: don't reset controller if Arbitration Lost detected
authorAlexander Kochetkov <al.kochet@gmail.com>
Sat, 22 Nov 2014 19:47:13 +0000 (23:47 +0400)
committerWolfram Sang <wsa@the-dreams.de>
Sun, 23 Nov 2014 16:27:48 +0000 (17:27 +0100)
commitb76911d2fe1462e1fc7c449e3e6aef76331e816e
tree761eb0013ee5b0d8e0f1e2438a19bd153058ec81
parent0f5768bf894f853c21e5f336b5f495599172f39b
i2c: omap: don't reset controller if Arbitration Lost detected

Arbitration Lost is an expected situation in a multimaster
environment. I2C controller (IP) correctly detect and report AL.

The only one visible reason for resetting IP in the AL case is
to avoid advisory 1.94 (omap3) and errata i595 (omap4): "I2C:
After an Arbitration is Lost the Module Incorrectly Starts
the Next Transfer".

Errata workaround states: "The MST and STT bits inside I2C_CON
should be set to 1 at the same moment (avoid setting the MST bit
to 1 while STT = 0)." The driver never set MST and STT bits
separately and doesn't create condition for errata. So the reset
is not necessary.

Also corrected return value for AL to -EAGAIN.

Tested on Beagleboard XM C.
Tested on BBB and AM437x Starter Kit by Felipe Balbi.

Signed-off-by: Alexander Kochetkov <al.kochet@gmail.com>
Tested-by: Felipe Balbi <balbi@ti.com>
Reviewed-by: Felipe Balbi <balbi@ti.com>
Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
drivers/i2c/busses/i2c-omap.c