power: bq25890: Enable continuous conversion for ADC at charging
authorYauhen Kharuzhy <jekhor@gmail.com>
Sun, 7 Nov 2021 20:20:01 +0000 (23:20 +0300)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 27 Jan 2022 08:00:58 +0000 (09:00 +0100)
commita5eae259db3500d36db601e73a68abb7f7de1ad6
tree949ba84e8f36fc0d34a4a936cd44077759cf0b72
parent00d65478a0c4b28baf4506ed6415fd4f8fe01e56
power: bq25890: Enable continuous conversion for ADC at charging

[ Upstream commit 80211be1b9dec04cc2805d3d81e2091ecac289a1 ]

Instead of one shot run of ADC at beginning of charging, run continuous
conversion to ensure that all charging-related values are monitored
properly (input voltage, input current, themperature etc.).

Signed-off-by: Yauhen Kharuzhy <jekhor@gmail.com>
Reviewed-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
drivers/power/supply/bq25890_charger.c