dt-bindings: rng: clocks property on omap_rng not always mandatory
authorThomas Petazzoni <thomas.petazzoni@free-electrons.com>
Fri, 17 Mar 2017 12:58:39 +0000 (13:58 +0100)
committerHerbert Xu <herbert@gondor.apana.org.au>
Fri, 24 Mar 2017 13:51:32 +0000 (21:51 +0800)
commit74d1cf4897f919837efc4e34d800b996936eb38e
tree2b70a6fe1be241360d873fbaa61b45dba449d433
parent8c75704ebcac2ffa31ee7bcc359baf701b52bf00
dt-bindings: rng: clocks property on omap_rng not always mandatory

Commit 52060836f79 ("dt-bindings: omap-rng: Document SafeXcel IP-76
device variant") update the omap_rng Device Tree binding to add support
for the IP-76 variation of the IP. As part of this change, a "clocks"
property was added, but is indicated as "Required", without indicated
it's actually only required for some compatible strings.

This commit fixes that, by explicitly stating that the clocks property
is only required with the inside-secure,safexcel-eip76 compatible
string.

Fixes: 52060836f79 ("dt-bindings: omap-rng: Document SafeXcel IP-76 device variant")
Cc: <stable@vger.kernel.org>
Signed-off-by: Thomas Petazzoni <thomas.petazzoni@free-electrons.com>
Signed-off-by: Herbert Xu <herbert@gondor.apana.org.au>
Documentation/devicetree/bindings/rng/omap_rng.txt