power: supply: axp20x_battery: properly report current when discharging
authorEvgeny Boger <boger@wirenboard.com>
Wed, 12 Jan 2022 08:47:27 +0000 (11:47 +0300)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 20 Apr 2022 07:08:26 +0000 (09:08 +0200)
commit724e76c087ac7855cf608f6c076cb99b3b1e9f07
treebc776282cec82d440bc4208f44c2ec641d002947
parentf33720070d2755d417779b81c60058023d6d2e3a
power: supply: axp20x_battery: properly report current when discharging

[ Upstream commit d4f408cdcd26921c1268cb8dcbe8ffb6faf837f3 ]

As stated in [1], negative current values are used for discharging
batteries.

AXP PMICs internally have two different ADC channels for shunt current
measurement: one used during charging and one during discharging.
The values reported by these ADCs are unsigned.
While the driver properly selects ADC channel to get the data from,
it doesn't apply negative sign when reporting discharging current.

[1] Documentation/ABI/testing/sysfs-class-power

Signed-off-by: Evgeny Boger <boger@wirenboard.com>
Acked-by: Chen-Yu Tsai <wens@csie.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
drivers/power/supply/axp20x_battery.c