OMAP4: PM: TWL6030: fix ON/RET/OFF voltages
authorPatrick Titiano <p-titiano@ti.com>
Wed, 18 May 2011 05:17:33 +0000 (00:17 -0500)
committerKevin Hilman <khilman@ti.com>
Thu, 15 Sep 2011 19:09:37 +0000 (12:09 -0700)
commit63f60a43e640c2f56be902c69503ea28d1010416
tree6ada8a21f5181193e89bb3ef58f53e8073c9b3ff
parent2aed5b9e8877237886453f138be7ecea224b32b0
OMAP4: PM: TWL6030: fix ON/RET/OFF voltages

According to latest OMAP4430 Data Manual v0.4 dated March 2011:
 - Retention voltage shall be set to 0.83V. See tables 2.2, 2.4 and 2.6 in DM.
   This allows saving a little more power in retention states.
 - OPP100 IVA nominal voltage is 1.188V. See table 2.4 in DM.
   This allows saving a little power when CPU wakes up until Smart-Reflex is
   not yet resumed.

[nm@ti.com: ported to voltdm_c]
Signed-off-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Patrick Titiano <p-titiano@ti.com>
arch/arm/mach-omap2/omap_twl.c