[S390] fix system call parameter functions.
syscall_get_nr() currently returns a valid result only if the call
chain of the traced process includes do_syscall_trace_enter(). But
collect_syscall() can be called for any sleeping task, the result of
syscall_get_nr() in general is completely bogus.
To make syscall_get_nr() work for any sleeping task the traps field
in pt_regs is replace with svcnr - the system call number the process
is executing. If svcnr == 0 the process is not on a system call path.
The syscall_get_arguments and syscall_set_arguments use regs->gprs[2]
for the first system call parameter. This is incorrect since gprs[2]
may have been overwritten with the system call number if the call
chain includes do_syscall_trace_enter. Use regs->orig_gprs2 instead.
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>