ARM: dts: r8a73a4: Remove unnecessary clock-output-names properties
* Fixed rate and fixed factor clocks do not require an
clock-output-names property.
* Since
07705583e920fef6 ("clk: shmobile: div6: Make clock-output-names
optional") Renesas div6 clocks do not require a clock-output-names
property.
In the above cases there is only one clock output and its name is taken
from that of the clock node. Accordingly, remove the unnecessary
clock-output-names properties and as necessary update the node names.
The clock-output-names property is left in place for the zb_clk which is
thus treated as a special case as the MSTP clock driver (clk-mstp.c)
explicitly looks for a clock with node name zb_clk for the r8a73a4 and
sh73a0 SoCs.
Signed-off-by: Simon Horman <horms+renesas@verge.net.au>
Acked-by: Geert Uytterhoeven <geert+renesas@glider.be>