ARM: EXYNOS: Correct M-5MOLS sensor clock frequency on Universal C210 board
authorSylwester Nawrocki <s.nawrocki@samsung.com>
Tue, 31 Jan 2012 03:58:31 +0000 (12:58 +0900)
committerKukjin Kim <kgene.kim@samsung.com>
Tue, 31 Jan 2012 03:58:31 +0000 (12:58 +0900)
commit3e8ad5610c07f88bdecf94468929c86631be476f
treec4db85f30d7b7df685c85add8c021ad213568b5b
parent7cc98aaea4ce040f119457f5b0bb9487acfb5205
ARM: EXYNOS: Correct M-5MOLS sensor clock frequency on Universal C210 board

In order to keep the sensor's master clock frequency in valid range
when FIMC parent clock is xusbxti, the specified frequency must be
exactly 24MHZ, otherwise it's being set to too low value due to
rounding.

Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
arch/arm/mach-exynos/mach-universal_c210.c