ARM: dts: imx7d-sdb: config the max pressure for tsc2046
authorHaibo Chen <haibo.chen@nxp.com>
Mon, 25 Jul 2022 10:16:22 +0000 (18:16 +0800)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 26 Oct 2022 11:17:11 +0000 (13:17 +0200)
commit3c3ff91f8f19aa0b648d2c720009ed26ff198822
tree5d53cba138f2d3977e52e7b4d747abbf947f5232
parent5547d093e6defc343c472779c4c505d5177e18c2
ARM: dts: imx7d-sdb: config the max pressure for tsc2046

[ Upstream commit e7c4ebe2f9cd68588eb24ba4ed122e696e2d5272 ]

Use the general touchscreen method to config the max pressure for
touch tsc2046(data sheet suggest 8 bit pressure), otherwise, for
ABS_PRESSURE, when config the same max and min value, weston will
meet the following issue,

[17:19:39.183] event1  - ADS7846 Touchscreen: is tagged by udev as: Touchscreen
[17:19:39.183] event1  - ADS7846 Touchscreen: kernel bug: device has min == max on ABS_PRESSURE
[17:19:39.183] event1  - ADS7846 Touchscreen: was rejected
[17:19:39.183] event1  - not using input device '/dev/input/event1'

This will then cause the APP weston-touch-calibrator can't list touch devices.

root@imx6ul7d:~# weston-touch-calibrator
could not load cursor 'dnd-move'
could not load cursor 'dnd-copy'
could not load cursor 'dnd-none'
No devices listed.

And accroding to binding Doc, "ti,x-max", "ti,y-max", "ti,pressure-max"
belong to the deprecated properties, so remove them. Also for "ti,x-min",
"ti,y-min", "ti,x-plate-ohms", the value set in dts equal to the default
value in driver, so are redundant, also remove here.

Signed-off-by: Haibo Chen <haibo.chen@nxp.com>
Signed-off-by: Shawn Guo <shawnguo@kernel.org>
Signed-off-by: Sasha Levin <sashal@kernel.org>
arch/arm/boot/dts/imx7d-sdb.dts