can: sja1000: clear interrupts on start
authorMirza Krak <mirza.krak@hostmobility.com>
Tue, 10 Nov 2015 13:59:34 +0000 (14:59 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 9 Dec 2015 18:40:09 +0000 (13:40 -0500)
commit3b792c868153a9911e46ec3069b7b94e7cc5c6c6
tree68f65c315ca93c31e8b0226147618d45f5bcc660
parentc45820774f2d7f3196c7ad371b026c2b6e93c9a7
can: sja1000: clear interrupts on start

commit 7cecd9ab80f43972c056dc068338f7bcc407b71c upstream.

According to SJA1000 data sheet error-warning (EI) interrupt is not
cleared by setting the controller in to reset-mode.

Then if we have the following case:
- system is suspended (echo mem > /sys/power/state) and SJA1000 is left
  in operating state
- A bus error condition occurs which activates EI interrupt, system is
  still suspended which means EI interrupt will be not be handled nor
  cleared.

If the above two events occur, on resume there is no way to return the
SJA1000 to operating state, except to cycle power to it.

By simply reading the IR register on start we will clear any previous
conditions that could be present.

Signed-off-by: Mirza Krak <mirza.krak@hostmobility.com>
Reported-by: Christian Magnusson <Christian.Magnusson@semcon.com>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/net/can/sja1000/sja1000.c