mfd: cros ec: spi: Don't send first message too soon
commit
15d8374874ded0bec37ef27f8301a6d54032c0e5 upstream.
On the Tegra124 Nyan-Big chromebook the very first SPI message sent to
the EC is failing.
The Tegra SPI driver configures the SPI chip-selects to be active-high
by default (and always has for many years). The EC SPI requires an
active-low chip-select and so the Tegra chip-select is reconfigured to
be active-low when the EC SPI driver calls spi_setup(). The problem is
that if the first SPI message to the EC is sent too soon after
reconfiguring the SPI chip-select, it fails.
The EC SPI driver prevents back-to-back SPI messages being sent too
soon by keeping track of the time the last transfer was sent via the
variable 'last_transfer_ns'. To prevent the very first transfer being
sent too soon, initialise the 'last_transfer_ns' variable after calling
spi_setup() and before sending the first SPI message.
Signed-off-by: Jon Hunter <jonathanh@nvidia.com>
Reviewed-by: Brian Norris <briannorris@chromium.org>
Reviewed-by: Douglas Anderson <dianders@chromium.org>
Acked-by: Benson Leung <bleung@chromium.org>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>