can: janz-ican3: avoid firmware lockup caused by infinite bus error quota
authorIra W. Snyder <iws@ovro.caltech.edu>
Wed, 18 Jul 2012 22:33:17 +0000 (15:33 -0700)
committerMarc Kleine-Budde <mkl@pengutronix.de>
Fri, 20 Jul 2012 15:49:05 +0000 (17:49 +0200)
commit30df5888e4a244093c1b403b55ef889c97824f7b
tree0a72a7baf1848b142cefb54ced268d600af655c8
parent83702f69272e4591a91a27eb58eade1bcd361dae
can: janz-ican3: avoid firmware lockup caused by infinite bus error quota

If the bus error quota is set to infinite and the host CPU cannot keep
up, the Janz VMOD-ICAN3 firmware will stop responding to control
messages until the controller is reset.

The firmware will automatically stop sending bus error messages when the
quota is reached, and will only resume sending bus error messages when
the quota is re-set to a positive value.

This limitation is worked around by setting the bus error quota to one
message, and then re-setting the quota to one message every time a bus
error message is received. By doing this, the firmware never stops
responding to control messages. The CAN bus can be reset without a
hard-reset of the controller card.

Signed-off-by: Ira W. Snyder <iws@ovro.caltech.edu>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
drivers/net/can/janz-ican3.c